Denso Power Net Terminal BHT-7500 Especificações Página 419

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 560
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 418
410
[ 5 ] Check Wireless Communications Device Synchronization
with Master
Using a wireless communications device for TCP/IP communication requires synchronizing
with the master (e.g., access point). To check the synchronization, use the extension library
SS.FN3.
In any of the following cases, a wireless communications device may not be synchronized with
the master:
When a wireless communications device is opened (Opening a wireless communications
device and synchronizing with the master will take a few seconds.)
When a wireless block tries to synchronize with a new master in roaming.
When a wireless block is moved out of the radio-wave area with the master.
When a wireless block is moved to a place where there is any radio-wave obstruction
between the wireless block and the master.
For details about SS.FN3, refer to Section 17.4, "Wireless Communication Library (SS.FN3)."
Given below is a setting example using SS.FN3.
timeout% = 100 Set time (10 sec.) to wait for
synchronization with master.
call "ss.fn3" 7 timeout%, assoc% Check synchronization with master.
(SS.FN3 function #7)
Returns value in assoc%
if assoc% = -1 then If synchronization is not complete, go
goto Sync.Erro to Sync.Err.
endif
Vista de página 418
1 2 ... 414 415 416 417 418 419 420 421 422 423 424 ... 559 560

Comentários a estes Manuais