18. Data Communication
The following communication interfaces can be used for communication with the host computer. Of the three
listed below, the IrDA interface and connector interface can be used with the CommSerial class and
FileTransfer class in order to create applications.
IrDA interface (IrDA-SIR1.2)
Connector interface
USB interface
18.1. IrDA Interface
The IrDA interface is assigned to port no. 4.
Communication
Parameter
Setting Default
Transmission
speed (bps)
115200, 57600, 38400, 19200, 9600 115200
The IrDA interface conforms to an IrDA physical layer (IrDA-SIR1.2), and therefore parameters other than
transmission speed are all fixed (vertical parity = none, character length = 8 bits, stop bit length = 1 bit).
18.2. Connector Interface
The connector interface is assigned to port no. 1.
Communication
Parameter
Setting Default
Transmission
speed (bps)
115200, 57600, 38400, 19200, 9600, 4800, 2400, 1200, 600, 300 115200
Vertical parity None, even number, odd number None
Data length 7 bits, 8 bits 8
Stop bit length 1 bit, 2 bits 1
RTS and CTS signal lines are not supported.
18.3. File Transfer
The FileTransfer class can be used to create a file transfer application using Y-modem communication.
In addition to the file itself, the “filename” and “file update date” are also transferred. If, however, the application
at the computer side is not compatible with the file update date, the transfer time will be set for both uploading