216
Pressing the M1 key (key number 30) while holding down the shift key functions as a
backlight on/off control key by default.
If pressed together with the shift key, any numerical key can operate as a function key.
onduration is the length of time in seconds from when the backlight is turned on to
automatic turning-off. Pressing the trigger switch or any key (except for the backlight
function on/off key) while the backlight is on resets the counter of onduration to the
specified time length and restarts counting down.
Specification of BL0 disables the backlight function. Specification of BL255 keeps the
backlight on.
A function key defined as a backlight function on/off key cannot be used to enter string
data.
• If you issue more than one KEY statement, the last statement takes effect. That is, if you
define more than one key as a backlight function on/off key as shown below, only the
function key numbered 8 operates as a backlight function on/off key and the length of
backlight ON-time is 15 seconds.
KEY 5,"BL40"
KEY 8,"BL15"
Defining a magic key as a trigger switch, shift key, or battery voltage display key
KEY in syntax 3 defines a magic key as a trigger switch, shift key, or battery voltage
display key, as well as assigning string data.
KEY 30,"TRG"
KEY 31,"SFT"
KEY 35,"BAT"
’M1 key as a trigger switch
’M2 key as a shift key
’M3 key as a battery voltage display key