244
□
□□
□Auto-off mode (F)
OPEN "BAR :F"AS #7 CODE "A"
If you press the trigger switch
*1
, the illumination LED
*2
comes on. When you release
the switch or when the BHT completes bar code reading, then the illumination LED will
go off. Holding down the trigger switch
*1
lights the illumination LED for a maximum of
5 seconds.
While the illumination LED is on, the BHT can read a bar code until a bar code is read
successfully or the bar code devices file becomes closed.
If the illumination LED goes off after 5 seconds from when you press the trigger switch
*1
, it is necessary to press the trigger switch
*1
again for reading a bar code.
Once a bar code is read successfully, pressing the trigger switch
*1
cannot turn on the
illumination LED
*2
and the BHT cannot read the next bar code as long as the entered
bar code data is not read out from the barcode buffer.
□
□□
□Alternate switching mode (A)
OPEN "BAR :A"AS #7 CODE "A"
If you press the trigger switch
*1
, the illumination LED
*2
comes on. Even if you release
the switch, the illumination LED
*2
remains on until the bar code device file becomes
closed or you press that switch again. While the illumination LED
*2
is on, the BHT can
read a bar code.
Pressing the trigger switch
*1
toggles the illumination LED
*2
on and off.
Once a bar code is read successfully, pressing the trigger switch
*1
turns on the
illumination LED
*2
but the BHT cannot read the next bar code as long as the entered
bar code data is not read out from the barcode buffer.
□
□□
□Continuous reading mode (C)
OPEN "BAR :C"AS #7 CODE "A"
Upon execution of the above statement, the BHT turns on the illumination LED
*2
and
keeps it on until the bar code device file becomes closed, irrespec-tive of the trigger
switch
*1
.
While the illumination LED
*2
is on, the BHT can read a bar code.
Once a bar code is read successfully, the BHT cannot read the next bar code as long
as the entered bar code data is not read out from the barcode buffer.
*1
The trigger switch function is assigned to the magic keys.
*2
The illumination LED may not come on where the environment is bright enough for
the BHT to scan.