248
CD is a check digit. Specifying a C to CD makes the Interpreter check bar codes with
MOD-16. The check digit is included in the number of digits.
OPEN "BAR :"AS #1 CODE "N :8AAC"
□
□□
□Code 39 (
((
(M)
))
)
Syntax:
M[:[mini.no.digits[-max.no.digits]][CD]
[,[mini.no.digits[-max.no.digits]][CD]]
[,[mini.no.digits[-max.no.digits]][CD]]]
where
mini.no.digits and max.no.digits are the minimum and maximum numbers of
digits for bar codes to be read by the BHT, respectively.
They should be a numeral from 1 to 99, excluding start/stop characters. They should
satisfy the following condition:
mini.no.digits •max.no.digits
If both of mini.no.digits and max.no.digits are omitted, then the default
reading range is 1 to 99 digits. If only max.no.digits is omitted, the BHT can only
read the number of digits specified by mini.no.digits.
CD is a check digit. Specifying a C to CD makes the Interpreter check bar codes with
MOD-43. The check digit is included in the number of digits.
OPEN "BAR:"AS #1 CODE "M:8-12C"
□
□□
□Code 93 (
((
(L)
))
)
Syntax:
L[:[mini.no.digits[-max.no.digits]
[,[mini.no.digits[-max.no.digits]]
[,[mini.no.digits[-max.no.digits]]]
where
mini.no.digits and max.no.digits are the minimum and maximum numbers of
digits for bar codes to be read by the BHT, respectively.
They should be a numeral from 1 to 99, excluding start/stop characters and check
digits. They should satisfy the following condition:
mini.no.digits •max.no.digits
If both of mini.no.digits and max.no.digits are omitted, then the default
reading range is 1 to 99 digits. If only max.no.digits is omitted, the BHT can only
read the number of digits specified by mini.no.digits.
OPEN "BAR:"AS #1 CODE "L:6-12"
Neither start/stop characters nor check digits will be transferred to the barcode buffer.