84
BHT-825Q series
“4:CODE39”Detailed settings for Code 39
1. Select “4: CODE39” at SET BARCODE menu and then press the ENT
key.
SET CODE39 screen displays.
1MIN”
Set minimum number of digits of Code 39
Setting range 199
“2MAX”
Set maximum number of digits of Code 39
Setting range 199
Point Set the value of minimum number of digits less than that of maximum number of digits. If the
value of minimum munber of digits is larger than that of maximum munber of digits, erro
r
occurs when reading.
“3CD CHECK”
“ON” It reads only when check digits are correct. It doesn’t read when check digits are not corrct
or no check digits are found.
“OFF”It reads whether check digits are found or not.
2. Use the cursor keys ([] []) or numerical keys ([1] [2] [3]) to select the item to be set.
3. Use the cursor keys ([] []) to select settings value.
4. Press the ENT key or BS/C key for the settings value to be valid and then return to the SET
BARCODE screen.