30
7.2.2 Data conversion mode
If the scanner reads a barcode specified by the “Code type” in this mode, it searches the data read for the
specified string (max. 16 ASCII characters), substitutes it with the specified conversion string (max. 16 ASCII
characters), and outputs it in the data transmission format selected in the scanner (see Chapter 9, Section 9.4).
Conversion conditions
Conversion conditions Setting data
Any code
UPC-A/EAN-13
UPC-E
EAN-8
CODE128
GS1-128 (EAN-128)
CODABAR (NW-7)
CODE39
Interleaved 2 of 5(ITF)
Standard 2 of 5(STF)
CODE32
CODE93
MSI
Plessey
“Code type”
GS1 DataBar (RSS)
Search string and conversion string Max.16 ASCII characters (00h to FFh) each
Example Code type : CODE128, Data : 12345678
Header : STX, Terminator : ETX, Scanner ID : Disable, Code ID mark : Disable,
Transmission of the number of digits : Disable, Prefix / Suffix : None, BCC : Disable
Conversion condition Search string and Conversion string Output data
“Code type”:CODE128 2 → A
4 → B
[STX]1A3B5678[ETX]