(12) Parameter Selection for Data Verification and Data Editing
Item Parameter Default Reference
Data string verification
Verification method
Data block verification
Enabled
Preset master registration
Disabled
Starting point of data
string verification
1 to 999 digits
in ASCII characters
1 digit
Number of digits to be
verified for data string
verification
(Preset master registration
not made)
1 to 99 digits
in ASCII characters
99 digits
Starting point of data
block verification.
1 to 99 digits
in ASCII characters
1 digit
Disabled
Transmit code data
Transmission of result
when verification is OK
Transmit OK
Disabled
Transmit code data
Transmission of result
when verification is NG
Transmit NG
Enabled Retry of verification after
NG result
(2-poin verification only)
Disabled
Code type + barcode data
Verification range
Barcode data only
Chapter 7
Section 7.1
Applicable code for
data editing
Select from the codes
Any code
(NOTE 1)
Transmit data regardless of
edit result
Handling of edit errors
Transmit data only when
successful edit result
Data string mode
Data block mode
Data extraction mode
for editing
AI mode
First character
Last character
Start position of data
string extraction
Specified position
Last character
Specified “n”th digit
End position of data
string extraction
Specified position
Start of data string
to be extracted
1 to 9999 digits
in ASCII characters
1 digit
End of data string
to be extracted
1 to 9999 digits
in ASCII characters
9999 digits