Barcode Handy Scanner AT20B-SM AT21B-SM User’s Manual

Página 2

vi  When disconnecting the AC adapter from the wall socket, hold the AC adapter body not the power cable. The power cable may be broken, resulti

Página 3 - Contents

89 Chapter 12 Troubleshooting Trouble ① Cannot scan bar codes. ② Reading data is not right. ③ Code data cannot be displayed normally on the comp

Página 4

90 USB Keyboard interface : Trouble Cause Countermeasure ②③ The keyboard type selected not match one that is set up in the host computer.Select

Página 5 - Preface

91 Appendix 1 Specifications Item AT20B-SM / AT21B-SM Readable codes EAN-13, EAN-8, UPC-A, UPC-E, UPC/EAN with Add-on, Interleaved 2 of 5, Stan

Página 6 - Customer Registration

92 Appendix 2 Control Commands Control commands refer to commands that are exchanged between the host computer and the scanner via the communicati

Página 7 - SAFETY PRECAUTIONS

93 Transfer Direction Control Commands Scanner HostFunction U1 U2 U3 U4 U5 U6 U7 U8 Trigger switch control U1 : Auto-off mode U2 : Momen

Página 8

94 NG Mismatch Only if data output is set to “NG” when verified data does not match, this command will be transmitted when data scanned does not mat

Página 9

95 Appendix 3 Interface Specifications RS-232C interface D-Sub 9pin socket type  D-Sub 9pin plug type(Power supplied from host t

Página 10

96 USB interface TypeA USB connector (Viewed from pin side) Pin # Signal 1 5VDC 2 D- 3 D+ 4 GND  4 2 13

Página 11 - Care and Maintenance

Barcode Handy Scanner AT20B-SM AT21B-SM User’s Manual First Edition, November 2011 DENSO WAVE INCO

Página 12

1, Yoshiike, Kusagi, Agui-cho, Chita-gun, Aichi 470-2297, Japan http://www.denso-wave.com/

Página 13 - Chapter 2 Preparation

vii Care and Maintenance Proper Care of the reading window Dust or dirt accumulating on the clear plate of the barcode reading window will affect r

Página 14

1 Chapter 1 Names and Functions Note: The bottom case is not securely held in the scanner case when the interface cable and its conn

Página 15 - (1) AC adaptor-powered type

2 Chapter 2 Preparation 2.1 Operating Environment for the Use of USB Interface Using the scanner via the USB interface requires a host computer eq

Página 16 - 3.2 Using the USB Interface

3 2.2 Connecting the Interface Cable to the Scanner (1) Pull the connector cover of the interface cable off its connector as shown below. (2) Plug

Página 17

4 Chapter 3 Connection to the Host Computer 3.1 Using the RS-232C Interface (1) AC adaptor-powered type ①Connect the RS-232C interface cable to t

Página 18

5 3.2 Using the USB Interface The scanner receives and sends data from/to the host computer through the USB-COM interface or USB keyboard interface.

Página 19

6 3.2.1 Setting up the USB-COM interface Using the USB-COM interface requires installing the Active USB-COM port driver provided by DENSO WAVE to the

Página 20 -  Reading mode

7 3.2.2 Setting up the USB keyboard interface The USB keyboard interface requires the USB device class driver for HID (Human Interface Device) which

Página 21

8 Windows XP (1) Switch the computer on to run Windows XP. Log on as an Administrator. (2) Connect the scanner’s USB interface cable to the compute

Página 22 - Chapter 6 Reading Control

Copyright © DENSO WAVE INCORPORATED, 2011 All rights reserved. No part of this publication may be rep

Página 23 - 6.2 Software Control

9 Chapter 4 Reading Barcodes (1) Bring the reading window to a target barcode and press the trigger switch. The marker beam comes on, indicating

Página 24

10 Chapter 5 Setting Parameters You can customize the scanner by modifying communications, code type, and other scanner parameters with the bar co

Página 25 - 7.1 Data Verification Mode

11 Chapter 6 Reading Control Two types of reading controls are available--Trigger switch control and Software control. Trigger switch control: Pre

Página 26

12 6.2 Software Control You can control the scanner by sending reading control commands from the host computer via the RS-232C or USB-COM interface,

Página 27 - (2) Data block verification

13 Note: Even if you do not bring a barcode label within the scan range, the illumination LEDs may come on when the ambient level of light changes or

Página 28

14 Chapter 7 Reading Functions 7.1 Data Verification Mode The data verification mode verifies the barcode data read against the master data stored

Página 29 - 7.2 Data Editing

15  2-point verification Scan master registration 1) Switch the scanner to the data verification mode and select the RS-232C or USB-COM interface.

Página 30

16 7.1.2 Specifying a verification object You can specify two types of verification objects--data string and data block. For data string verification

Página 31 -  Data block numbers

17 7.1.3 Verification result output (1) Report of match / mismatch status You can select any of the following report types using the configuration s

Página 32

18 7.2 Data Editing You can edit and output code data read, in any of the three data edit modes--“data extraction mode,” “data conversion mode” and “

Página 33 -  Delimiters

Contents Preface...

Página 34

19  Extraction start and end positions “Extraction start position” “Extraction end position” Head position Tail position nth position Tail position

Página 35 - (2) AI parenthesizing mode

20 7.2.1.2 Extracting data blocks If data read is in the comma-delimited CSV format, the scanner extracts data blocks specified by the data block num

Página 36 - (3) AI table

21 Example Code type : CODE128, Data : (See the table below.) Header : STX, Terminator : ETX, Scanner ID : Disable, Code ID mark : Disable, Tr

Página 37

22 7.2.1.3 Extracting AI (Application Identifier)-prefixed strings If the scanner reads any of GS1-128 (EAN-128) and GS1DataBar (RSS) symbols, it edi

Página 38

23 Example Data read : (01)94901234567894(11)030808(13)030810(17)040208(17)040305 Header : STX, Terminator : ETX, Scanner ID : Disable, Code ID ma

Página 39

24 (2) AI parenthesizing mode In this mode, the scanner parenthesizes AI contained in data read and outputs the edited data according to the extracti

Página 40

25 (3) AI table In the AI-prefixed string extraction, the scanner edits data according to the Application Identifiers (AI) defined below. AI Format

Página 41 -  Conversion conditions

26 AI Format Description 320n n4+n6 Net Weight, Pounds (***) 321n n4+n6 Length or 1st Dimension, Feet (***) 322n n4+n6 Length or 1st Dimension, Y

Página 42 -  Block sorting conditions

27 AI Format Description 353n n4+n6 Area, Square Inches, Logistics (***) 354n n4+n6 Area, Square Feet, Logistics (***) 355n n4+n6 Area, Square

Página 43 - 8.1 Beeper

28 AI Format Description 421 n3+n3+an..9 Ship to (Deliver to) Postal Code with Three-Digit ISO Country Code Prefix 422 n3+n3 Country of Origin of a

Página 44 - 8.2 Indicator LED

Chapter 10 Parameters and Defaults ...52 Chapter 1

Página 45

29 AI Format Description 91 n2+an..30 Company Internal Information--Company 92 n2+an..30 Company Internal Information--Company 93 n2+an..30 Company

Página 46

30 7.2.2 Data conversion mode If the scanner reads a barcode specified by the “Code type” in this mode, it searches the data read for the specified s

Página 47 - Chapter 9 Communication

31 7.2.3 Block sorting mode The scanner splits barcode data read into a maximum of 5 blocks at the specified separate positions, sorts those blocks i

Página 48 - 9.2 USB-COM Interface

32 Chapter 8 Beeper, Indicator LED 8.1 Beeper (1) Beeping The scanner emits a short or long beeps, once or a couple of times as described below. (

Página 49 -  Communication protocols

33 8.2 Indicator LED The indicator LED lights or flashes in blue, green or red with scanner status. (Refer to Section 8.3 for details of indicator LE

Página 50 - 9.3 USB Keyboard Interface

34 8.3 Beeping, Indicator LEDs with scanner status Normal operation Status Beeping Indication LED A read of a bar code is successfully complete 1

Página 51 - 9.4 Communication Format

35 Status Beeping Indication LED No master data has been registered in the n-point verification scan mode Lights in red (Repeating)

Página 52 - (5) Code ID mark

36 Chapter 9 Communication 9.1 RS-232C Interface With the RS-232C interface being selected, the scanner uses asynchronous data transmission and co

Página 53

37 9.2 USB-COM Interface This scanner is compliant with USB 1.1 (Universal Serial Bus Specification Revision 1.1). Installing the dedicated Active US

Página 54 - (7) Code data

38  Communication protocols You can select either no protocol mode or ACK/NAK mode. No protocol mode (default) If the CTS signal is at a high level

Página 55

i Preface Thank you for using the AT20B / AT21B DENSO WAVE Barcode Handy Scanner. Please read through this manual carefully. It will enable you to op

Página 56

39 9.3 USB Keyboard Interface The USB keyboard interface requires no dedicated device driver. Data read by the scanner can be entered to the cursor p

Página 57

40 9.4 Communication Format Select one of the following two data transmission formats. No. of digit Header Scanner ID Code ID mark Prefixn1 n2 n3 N4C

Página 58 - 9.5 GTIN Format Conversion

41 (5) Code ID mark This optional field specifies the code ID mark identifying a barcode symbology. Five types of code ID marks (Type 1, Type 2, Typ

Página 59

42 CODABAR (NW-7) N C ]Fm CODE93 L E ]G0 CODE128 K D ]Cm GS1-128 (EAN-128) W K ]C1 MSI P J ]Mm Plessey T ]P0 GS1 DataBar (RSS)(Note1) R

Página 60

43 (6) Number of digits Indicates the number of barcode data digits in four digits (four bytes) or two digits (two bytes), however, the number of di

Página 61

44 UPC-E You can select whether or not to transmit the padding character “0,” number system character “S,” and a check digit to the host. Disabling t

Página 62

45 EAN-13 You can select whether or not to transmit the two prefix characters “P1” and “P2” and a check digit to the host. The conversion to the ISBN

Página 63 - (NOTE 1)

46 EAN-8 with add-on A code ID mark precedes add-on code data under the conditions “Code ID mark: Type 4” and “Code ID mark output mode: Separating.”

Página 64

47 9.5 GTIN Format Conversion Enabling the GTIN (Global Trade Item Number) format conversion allows UPC-A, UPC-E, EAN-13, EAN-8, and Interleaved 2 of

Página 65

48 UPC-E Data read 0 X1 X2 X3 X4 X5 X6 C/D 0 : Adjust the number of digits Conversion to 16-digit GTIN format (AI “01” and PI added) X6=0 - 2

Página 66 - Lower digit

ii Customer Registration and Inquiries Customer Registration To allow us to provide our customers with comprehensive service and support, we request

Página 67

49 EAN-13 Data read P1 P2 P3 X1 X2 X3 X4 X5 X6 X7 X8 X9 C/D Pn : Prefix characters Conversion to 16-digit GTIN format (AI “01” and PI added) 0 1 PI P

Página 68

50 EAN-8 with add-on Data read With 2-digit add-on: P1 P2 X1 X2 X3 X4 C/D X5 X6 With 5-digit add-on: P1 P2 X1 X2 X3 X4 C/D X5 X6 X7 X8 X9 Pn : Prefix

Página 69

51 (2) Conversion from GS1 DataBar (RSS) / GS1-128 (EAN-128) in GTIN format to EAN format GS1 DataBar (RSS) or GS1-128 (EAN-128) data read in the GT

Página 70 - UPC-A/E、EAN-13/8

52 Chapter 10 Parameters and Defaults Parameters in the chart below can be selected with Bar coded parameter menu or configuration software (Scann

Página 71 - Standard 2 of 5

53 (3) RS-232C Interface Parameter Selection Only valid when Interface Selection has been selected RS-232C interface. Item Parameter Default Refe

Página 72 - CODABAR(NW-7)

54 (5) USB keyboard Interface Parameter Selection Only valid when Interface Selection has been selected USB keyboard interface. Item Parameter Def

Página 73 - CODE128, GS1-128 (EAN-128)

55 Item Parameter Default Reference Enabled Special key transmission mode Disabled  (NOTE 4) 1 msec  5 msec 10 msec 15 msec 30 msec

Página 74 - GS1 DataBar (RSS)

56 (6) Data Transmission Format Selection Common to All the Interfaces Item Parameter Default Reference Enabled Code mark transmission Disabled 

Página 75

57 (7) Data Transmission Format Selection for RS-232C/USB-COM Item Parameter Default Reference None  STX Header User-defined None ETX CR

Página 76

58 (8) Data Transmission Format Selection for USB Keyboard Interface Item Parameter Default Reference None  STX ETX CR LF CR + LF TAB ESC E

Página 77

iii SAFETY PRECAUTIONS Be sure to observe all these safety precautions.  Please READ through these instructions carefully. They will enable you to u

Página 78

59 (9) Barcode Selections UPC-A/E、EAN-13/8 Item Parameter Default Reference Enabled  Reading UPC-A & EAN-13 Disabled Chapter 9 Section 9.4 Ena

Página 79 - Three beeps

60 Item Parameter Default Reference Enabled  Reading EAN-8 Disabled Chapter 9 Section 9.4 Enabled  C/D transmission of EAN-8 Disabled Enable

Página 80 - USB interface to the host

61 CODABAR(NW-7) Item Parameter Default Reference Enabled without C/D  Enabled with C/D Reading CODABAR(NW-7) Disabled Enabled  C/D transmission

Página 81

62 CODE128, GS1-128 (EAN-128) Item Parameter Default Reference Enabled  Reading CODE128 Disabled Enabled  Reading GS1-128 (EAN-128) Disabled Chap

Página 82

63 Plessey Item Parameter Default Reference Enabled Reading Plessey Disabled  Single Mode of reading Plessey Dual  Minimum number of readable

Página 83

64 (10) Trigger Switch Control Item Parameter Default Reference Auto off mode  Momentary switching mode Momentary switching mode (Inverted type)

Página 84 - < Disable >

65 (11) Beeper and LED indicator Item Parameter Default Reference Enabled  Beeping sound Disabled Low(2.8 kHz) Medium(3.0 kHz)  Beeper frequency

Página 85

66 (12) Parameter Selection for Data Verification and Data Editing Item Parameter Default Reference Data string verification  Verification method

Página 86

67 Item Parameter Default Reference Number of extracted digits (3 blocks max) 1 to 99 digits in ASCII characters Not definedNOTE 1 : “Any code” mea

Página 87

68 Chapter 11 Bar coded Parameter Menu 11.1 Parameter Setting Procedure Using the Bar coded Parameter Menu Start setting Use the scanner to scan t

Página 88

iv To System Designers:  When introducing the scanner in those systems that could affect human lives (e.g., medicines management system), develop

Página 89 - ■ Data transmission format

69 11.2 Bar coded Parameter Menu Menu control (Starting/Ending the Setting Procedure and Reverting to Defaults) Start setting End setting

Página 90 - UPC-A/-E and EAN-13/-8

70 Communications parameters for RS-232C interface Procedure < No protocol mode > ACK/NAK mode Transmission speed 4800bps <

Página 91 - CODABAR (NW-7)

71 Stop bit < 1 bit > 2 bits CTS signal monitoring < Not controlled > Controlled Header < None > STX Termin

Página 92

72 Communications parameters for USB-COM interface Procedure < No protocol mode > ACK/NAK mode CTS signal monitoring < Not co

Página 93

73 Transmission of BCC < Disable > Enable

Página 94 - CODE128/GS1-128(EAN-128)

74 Communications parameters for USB keyboard interface Caps Lock mode < Manual(OFF) > Manual(ON) Auto Keyboard type < U.S.E

Página 95

75 Data trasmission interval < 1ms > 5ms 10ms 15ms 30ms 50ms 100ms Numeric data transmission format < Inboard numeric k

Página 96

76 Header (USB keyboard interface) < None > STX ETX CR LF CR+LF TAB ESC ENTER Right Ctrl ← ↑ → ↓

Página 97 - ■ Trigger switch control

77 Terminator (USB keyboard interface) None STX ETX CR LF CR+LF TAB ESC < ENTER > Right Ctrl ← ↑ → ↓

Página 98 - < Medium >

78 Data transmission format Transmission of code ID mark Enable < Disable > Tranmission of the number of digits Enable in 4 dig

Página 99 - ■ Beeper/Indicator LED

v Never disassemble  Never disassemble or modify the scanner; doing so could result in an accident such as break or fire. Doing so could resul

Página 100

79 UPC-A/-E and EAN-13/-8 Reading UPC-A, UPC-E, EAN-13 and EAN-8 < Enable > Disable Reading UPC/EAN add-on Enable in 2-digit add-on

Página 101

80 Interleaved 2 of 5 Reading Interleaved 2 of 5 < Enable without a chek digit > Enable with a check digit Disable Check digit transm

Página 102 - Appendix 1 Specifications

81 Transmission of start / stop codes for CODABAR (NW-7) < Transmit a/b/c/d > Transmit A/B/C/D Disable CODE32 Conversion from CODE39

Página 103 - Function

82 CODE39 Reading CODE39 < Enable without a check digit > Enable with a check digit Disable Check digit transmission < Enable

Página 104 - Scan entry remote request

83 CODE128/GS1-128(EAN-128) Reading CODE128/GS1-128(EAN-128) < Enable > Disable FNC1 transmission of CODE128 < Convert to GS bef

Página 105

84 Plessey Reading Plessey Enable < Disable > Reading type of Plessy < Dual > Single GS1 DataBar (RSS) Reading GS1 Da

Página 106 - (Viewed from pin side)

85 Reading GS1 DataBar Expanded Enable < Disable > Reading GS1 DataBar Expanded Stacked Enable < Disable > FNC1 transmi

Página 107

86 Trigger switch control Trigger switch control < Auto-off mode > Momentary switching mode Momentary switching mode(Reverse type)

Página 108 - Barcode Handy Scanner

87 Auto sensing barcode detection level High < Medium > Low

Página 109

88 Beeper/Indicator LED Beeper control < Enable > Disable Beeper frequency Low < Medium > High Beeper sound duratio