Denso RC5 Especificações Página 372

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 692
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 371
12-96
ST_ResetCompJLimit (Statement) [Ver.1.9 or later]
Function
Initializes the current limit under the compliance control (special compliance control
function statement) (exclusively designed for 6-axis robots).
Format
ST_ResetCompJLimit
Explanation
Initializes the current limit under the compliance control and set 0 to all axes.
Related Terms
ST_SetCompJLimit, ST_SetCompControl
Notes
(1) Execute this command in a TAKEARMed task that has obtained arm
semaphore. If this command is executed without arm semaphore obtained, Error
"21F7 Cannot take arm semaphore" will result.
Example
ST_ResetCompControl 'Disable the compliance control
ST_ResetCompJLimit 'Initialize the current limits