ST_ResetCompEralw (Statement) [Ver.1.9 or later]
Function
Initializes the allowable deviation values of the position and the posture of the tool
end under the compliance control (exclusively designed for 6-axis robots).
Format
ST_ResetCompEralw
Explanation
Initializes the allowable deviation values of the position and the posture of the tool tip
under the compliance control. The initial values of allowable deviation are 100 (mm)
along X, Y, and Z and 30 (degree) about X, Y, and Z.
Related Terms
ST_SetCompEralw
Notes
(1) Execute this command in a TAKEARMed task that has obtained arm
semaphore. If this command is executed without arm semaphore obtained, Error
"21F7 Cannot take arm semaphore" will result.
Example
ST_ResetCompEralw