Chapter 19 System Information
19-5
Related Terms
CLEARLOG, STOPLOG
Example
STARTLOG 'Starts recording of the servo control log.
CLEARLOG (Statement)
NOTE: Control log is greatly enhanced in Ver. 1.20 or later. If you use Ver.
1.20 or later, refer to “WINCAPSII Guide, Section 10.7, "New Control Log" on
page 10-27.
Function
Initializes recording of the servo control log.
Format
CLEARLOG
Explanation
Use the CLEARLOG command to instruct initialization of the servo control log
in the program.
You must clear (initialize) the contents of the log before restarting recording,
when the servo log record buffer is full or when program execution stops
because of an error. Refer to p.19-4 “ Log Operation Status Transition
Diagram.”
To record the servo control log without fail, execute the CLEARLOG command
before executing the STARTLOG command. After recording has started,
recording will not be possible even if you execute the STARTLOG command.
Related Terms
STARTLOG, STOPLOG
Example
CLEARLOG 'Initializes servo control log recording.