12-102
ST_ResetDampRate (Statement) [Ver.1.9 or later]
Function
Initializes the damping rates under the compliance control (exclusively designed for
6-axis robots).
Format
ST_ResetDampRate
Explanation
Initializes all damping rates along and about X, Y, and Z axes to 100.
Related Terms
ST_SetDampRate
Notes
(1) Execute this command in a TAKEARMed task that has obtained arm
semaphore. If this command is executed without arm semaphore obtained, Error
"21F7 Cannot take arm semaphore " will result.
(2) This command is not executable under the compliance control. If this command
is executed under the compliance control, then Error " 60FA Not Executable in
compliance control" will result.
Example
ST_ResetDampRate 'Initialize the damping rates