Denso RC5 Especificações Página 374

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 692
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 373
12-98
ST_ResetCompVMode (Statement) [Ver.1.9 or later]
Function
Disables the velocity control mode under the compliance control (special compliance
control function statement) (exclusively designed for 6-axis robots).
Syntax
ST_ResetCompVMode
Explanation
Disables the compliance velocity control mode when ST_SetCompControl is
executed.
Related Terms
ST_SetCompControl
Notes
(1) Execute this command in a TAKEARMed task that has obtained arm
semaphore. If this command is executed without arm semaphore obtained, Error
"21F7 Cannot take arm semaphore" will result.
Example
ST_ResetCompVMode 'Disable the compliance velocity control mode
ST_SetCompControl 'Enable the compliance control
Vista de página 373
1 2 ... 369 370 371 372 373 374 375 376 377 378 379 ... 691 692

Comentários a estes Manuais

Sem comentários